Phone +45 31 640 550 mail@prestonrentals.dk

SuperEnergyBox XS

SuperEnergyBox XS is the ideal solution for emission-free operation without a grid connection – compact, mobile and powerful.

Rental price per working day DKK 825

All prices are exclusive of VAT, insurance and environmental contributions.
Contact us for a quote
SuperEnergyBox model M

SuperEnergyBox XS is easy to transport by van or trailer.

The compact and powerful energy storage system is designed for off-grid use and delivers reliable performance under demanding conditions – from freezing winter temperatures to summer heat (-20 °C to 40 °C).

SuperEnergyBox XS is ideal for temporary power supply at construction sites, events, residential properties or remote locations without access to the power grid.

The system is particularly suitable for applications requiring high-voltage power where only a single-phase 230 V connection is available. Thanks to its robust and intelligent design, SuperEnergyBox XS delivers a stable power supply without the noise, exhaust emissions or hassle associated with traditional diesel generators.

Its compact size and high mobility make the system easy to transport by van or trailer. SuperEnergyBox XS is easy to install, ready for immediate use and provides reliable, fully electric power – anytime, anywhere.

Models

SuperEnergyBox XS 8-16

Grid voltage (50Hz):
230/400 VAC

Nominal capacity:
16.7 kWh

Nominal inverter power:
8 kW

Nominal output current:
11,6 A

Nominal 3-phase charging power:
8 kW

Dimensions (L x B x H):
828 x 490 x 1154 mm

Weight:
275 kg

SuperEnergyBox XS 12-33

Grid voltage (50Hz):
230/400 VAC

Nominal capacity:
33,4 kWh

Nominal inverter power:
12 kW

Nominal output current:
17,4 A

Nominal 3-phase charging power:
12 kW

Dimensions (L x B x H):
828 x 849 x 1154 mm

Weight:
425 kg

Specifications

Nominal single-phase load capacity: 1.8 kW (optional)

Current THD: < 3% (with linear load < 1.5%)

Power factor: 1

Standby consumption: < 2 W (battery)

Battery chemistry: Lithium iron phosphate (LiFePO₄)

DC battery voltage: 51.2 VDC

Depth of discharge (D.o.D.): 90%

Protection: Overload, overheating, overvoltage and undervoltage, insulation monitoring, AC and DC ground fault protection

Maintenance charging interval: 2 weeks

Operating temperature: -20°C ~ 40°C

Humidity (non-condensing): 0 to 95% RH

Maximum operating altitude: <1000 m

Cooling: Passive battery cooling, active inverter cooling

Cycle life (70% of nominal capacity): ≥ 6,000 cycles (0.5C/0.5C @ 25 °C and 90% DoD)

Handling: Lifting eyes (Ø40 mm) and provision for transport by forklift/pallet truck

PGS: PGS 37-1